SEW變頻器MOVITRAC-31C系列故障代碼詳表

發(fā)布時間:2019-08-02 15:40:26來源:

故障代碼 故障現(xiàn)象/類型 故障原因 解決對策
1 Overcurrent Short circuit/earth fault at the output. Motor too large. Faulty output stage. Remove short-circuit. Connect smaller motor. If fault can still not be reset, contact SEW service.
2 DC link voltage DC link voltage too high. Increase deceleration ramps.
3 Brake chopper Regenerative power too high Braking resistor circuit interrupted Short-circuit in the braking resistor circuit Braking resistance value too high Faulty brake chopper Increase deceleration ramps. Check connecting leads of the braking resistor. Check technical data of the braking resistor. Exchange MOVITRAC® 31C
5 Regenerative overload With active regen. n monit. (P520/P522) and speed control (P770): faulty encoder signals wrong number of pole pairs (P324/P344) value of increments (P773) not correct Check encoder. Check encoder connection. Set number of pole pairs correctly. Set value of increments correctly.
4 Cont. overload ´t utilization too high (> 125(%)). Reduce load.
6 Overtemperature Thermal overload of the inverter. Reduce load and / or ensure adequate cooling.
7 Phase failure With active mains volt. monitor.(P530) Phase missing at TL. X1:1/2/3. Check mains supply.
10 Direction of rotation Only with active speed control (P770): Encoder tracks A/A and B/B are swapped in pairs. Motor rotates in opposite direction. Regen. overload (i.e. with sagging hoist) because of excessive load or BOOST setting too low (P321/P341). Check encoder connection. Exchanging two motor phases. Reduce load or increase BOOST.
11 Speed detection Only with active speed control (P770): Faulty encoder connection. FEN31C/FPI31C option not installed. Check encoder connection. Insert correct option (FEN31C or FPI31C).
12 Mot. overload With active n monit. (P510/P512) and speed control (P770): faulty encoder signals wrong number of pole pairs (P324/P344) value of increments (P773) not correct Check encoder. Check encoder connection. Set number of pole pairs correctly. Set value of increments correctly.
13 Starting conditions With active hoist function (P710/P712): Current too low during the premagnetization phase: Motor rated power selected too small in relation to the inverter rated power. Cross-section of the motor leads too small. Check startup data and carry out new startup if necessary. Check inverter-motor connection. Check cross-section of the motor leads and increase if necessary.
14 Output open With active hoist function (P710/P712): Two or all output phases interrupted. Motor rated power selected too small in relation to the inverter rated power. Check inverter-motor connection. Check startup data and carry out new startup if necessary.
17 Stack overflow Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
18 Stack underflow Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
19 NMI trap Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
20 Undefined opcode Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
21 Protected instr. Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
22 Word op. access Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
23 nstruct. access Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly,
24 Ext. bus access Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.

故障代碼 故障現(xiàn)象/類型 故障原因 解決對策
25 EEPROM Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
26 No connection Inverter electronics faulty. Possible cause: EMC effect. The notes for EMC compliant installation must be observed. The reset for error 25 consists of several steps: 1. Factory setting (P830 = YES) 2. Re-set matched parameters 3. Carry out reset If fault occurs repeatedly, contact SEW service.
27 Ext. terminal External fault signal has appeared at a programmable input Eliminate the cause of the fault. Reprogram the terminal, if necessary
28 Fault INTERBUS FFI31C and control mode (P841) = Fieldbus: Faulty monitoring signal. Check Fieldbus connection.
32 Copying Only when copying the parameters (P820): Break or interference in PC or FBG31C connection. Check connection between inverter and PC. Remove FBG31C keypad and plug again.
33 Master-slave Connection master-slave is interrupted. 0V5 connection (RS-485) missing Master or slave defined incorrectly in P880. Check master-slave connection. 0V5-establish connection between master and slave Set P880 correctly.
34 Fieldbus timeout No communication between master and slave within the specified time of the response monitoring. Check communication routine of the master. Increase fieldbus timeout time (P571)/ deactivate monitoring.
35 Connection Encoder-FRS Encoder connection faulty. Power supply of the encoder faulty. Check encoder connection. Check power supply of the encoder.
36 Connection Master-slave Only with FRS and cable break master-slave (P557) = YES: Setpoint connection of slave (TL. 98-101) is disrupted. Master Speed 0 ® slave FRS CTRL is disrupted. Slave FRS CTRL input not assigned. Master Speed 0 output not assigned. No master inverter available. Encoder < 512 pulses per revolution used. Check installation. Check programming of the binary inputs and binary outputs. Check if encoder type is correct.
37 FRS RAM fault Internal fault. If fault occurs repeatedly, contact SEW service.
38 FRS process data fault Fault on interface between inverter and FRS. If fault occurs repeatedly, contact SEW service.
39 FRS parameter data fault Invalid value for FRS parameters (P55_). Check parameter settings.
41 FRS lag fault Polarity of the encoder not set correctly. Acceleration ramps too short. P-gain of the positioning controller too small Speed controller not set property. Value for lag error tolerance too small Change polarity of encoder. Increase ramps. Increase P-gain. Select new parameters for speed controller. Increase lag error tolerance (P551). Check wiring of encoder, motor and mains phases. Check if mechanical system is sluggish or whether drive hit an obstacle.
43 Fault binary output Load on TL. X3:61 > 150 mA. Load on the other binary outputs > 50 mA Short circuit on binary output. Capacitive load on binary output. Check installation of the binary outputs.
、、、、、、、長治變頻器維修、、、、信陽變頻器維修、、、,河南鄭州變頻器專業(yè)銷售維修中心,技術(shù)精湛,質(zhì)量可靠,價格比較低,信譽保證!變頻器維修電話:15515598858 0371-56700815
用手機看
SEW變頻器MOVITRAC-31C系列故障代碼詳表

拍下二維碼,信息隨身看

試試用手機掃一掃,
在你手機上繼續(xù)觀看此頁面。

主站蜘蛛池模板: 天天资源网| 米奇久久| 一区二区三区毛片免费| 91sex国产| 在线观看黄日本高清视频| 色婷婷精品综合久久狠狠| 欧美性猛交xxxx免费看手交| 国产精品三级一区二区| 最新激情网| 精品国产一区二区三区2021| 国产第一色| 一级特黄网站| 精品国产一区二区三区不卡蜜臂 | 99re视频在线| 日日干影院| aaa大片| 男女黄色毛片| 久久三级国产| 最近韩国日本免费| 黄色免费大全| 亚洲综合美腿丝国产一区| 狠狠婷婷综合缴情亚洲| 在线观看免费毛片| 韩国毛片免费| 看片992tv| 久久综合九九| 欧美成人中文字幕| 日日天天夜夜| 色婷婷小说网| 老湿机69免费福利区| 99精品国产高清一区二区| 日日干干| 337p日本欧洲亚洲大胆精品| 精品一区二区三区在线观看| 七月婷婷在线网址| 天天摸天天做天天爽免费视频| 激情综合五月亚洲婷婷| 一级毛片特黄久久免费看| yy4138理论片在线大全| 欧美激情一区| 伊人网综合在线观看|